AC DC IR 5kv program dielectric strength hipot tester
Appliance :
For a variety of production lines and test the necessary electrical safety tester, can quickly and accurately measure the electronic components, household appliances, insulation materials, instrumentation, lighting appliances, electric heating appliances of the safety of the test.
Main features:
1.Standard mode measurement system (ACW / DCW / IR / GR)
2.Standard preventive safety system (with OK lights, zero-crossing start)
3.High pressure indicator, voltage safety indicator column function
4.Fast voltage rise time (within 100ms)
5.Measurement of automatic stability control system
6.You can test the resistance, capacitive, emotional and other different load
7.0.2 seconds fast discharge function
8.Can set the voltage rise time, test time, pause time
9.With arc detection function, you can set the arc detection level
10.20 memory groups, each with 8 test steps
11.Multi-step test, the automatic cycle test can also be manual
12.Testing, applicable to different parts of the different requirements of the test
13.Start the number of reset records to prevent leak detection and new test statistics
14.50Hz, 60Hz frequency optional
15.Standard PLC interface, optional RS232 interface, RS485 interface, U disk storage work
Appliance :
For a variety of production lines and test the necessary electrical safety tester, can quickly and accurately measure the electronic components, household appliances, insulation materials, instrumentation, lighting appliances, electric heating appliances of the safety of the test.
Main features:
1.Standard mode measurement system (ACW / DCW / IR / GR)
2.Standard preventive safety system (with OK lights, zero-crossing start)
3.High pressure indicator, voltage safety indicator column function
4.Fast voltage rise time (within 100ms)
5.Measurement of automatic stability control system
6.You can test the resistance, capacitive, emotional and other different load
7.0.2 seconds fast discharge function
8.Can set the voltage rise time, test time, pause time
9.With arc detection function, you can set the arc detection level
10.20 memory groups, each with 8 test steps
11.Multi-step test, the automatic cycle test can also be manual
12.Testing, applicable to different parts of the different requirements of the test
13.Start the number of reset records to prevent leak detection and new test statistics
14.50Hz, 60Hz frequency optional
15.Standard PLC interface, optional RS232 interface, RS485 interface, U disk storage work
Model | BND9922N | BND9922AN | ||||||
ACW AC high voltage |
Output voltage |
range | 0.200kV~5.000kV | |||||
accuracy | ±(2%read+5V) | |||||||
resolution | 1V | |||||||
Maximum power | 60VA(5.000kV/12mA) | |||||||
Maximum test current | 12mA | |||||||
Low-current | 0~12mA,0=OFF | |||||||
Current Range | 2mA,12mA | |||||||
Waveform | Sine waveform | |||||||
Distortion | ≤2%( Unloaded or pure resistance of the load) | |||||||
Crest factor | 1.3~1.5 | |||||||
Waveform mode | DDS+ Amplifier | |||||||
Rise time | 0.3s~999.9s 0=OFF | |||||||
Test time | 0.3s~999.9s 0=Continuous test | |||||||
Interval time | 0.0s~999.9s 0=OFF | |||||||
ARC detection | 0~9,0=OFF | |||||||
DCW DC high voltage |
Output voltage |
range | 0.200kV~6.000kV | -------- | ||||
accuracy | ±(2%read +5V) | -------- | ||||||
resolution | 1V | -------- | ||||||
Maximum power | 30W(6.000kV/5mA) | -------- | ||||||
Maximum test current | 5mA | -------- | ||||||
Current Range | 2mA,5mA | -------- | ||||||
Ripple coefficient | ≤5% | -------- | ||||||
Discharge time | ≤200ms | -------- | ||||||
Maximum charge current | 5mA | -------- | ||||||
Voltage rise time | 0.3~999.9s 0=OFF | -------- | ||||||
Test time | 0.3~999.9s 0=continuous test | -------- | ||||||
Interval time | 0.0~999.9s 0=OFF | -------- | ||||||
ARC detection | 0~9,0=OFF | -------- | ||||||
IR insulation resistance test |
Output voltage | range | 0.05kV~1.00kV 10V each step | |||||
accuracy | ±(2%read+5V) | |||||||
resolution | 1V | |||||||
Upper limit set(max.) | 10.00GΩ | |||||||
Lower limit set(max.) | 10.00GΩ | |||||||
Lower limit set(min.) | 1MΩ | |||||||
Voltage rise time | 0.3s~999.9s 0=OFF | |||||||
Test time | 0.3s~999.9s 0=Continuous test | |||||||
Interval time | 0.0s~999.9s 0==OFF | |||||||
Discharge time | ≤200ms | |||||||
Volt meter |
range | 0.050kV~6.000kV | 0.050KV~5.000kV | |||||
Accuracy | ±(2%read+5V) | |||||||
Resolution | 1V | |||||||
Displayed value | RMS | |||||||
Ampere meter |
range | AC | 0 ~12.00mA | 0 ~12.00mA | ||||
DC | 0 ~ 10.00mA | ----------- | ||||||
resolution | AC | 2mA:1uA, 20mA:10uA | ||||||
DC | 2mA:1uA, 10mA:10uA |
----------- | ||||||
Accuracy | ±(2%+5counts) | |||||||
ohm meter | Range | 1MΩ~10.00GΩ | ||||||
Resolution | 1MΩ~9.99MΩ:0.01MΩ,10MΩ~99.9MΩ:0.1MΩ, 100MΩ~999MΩ:1MΩ,1.00GΩ~10.00GΩ:10MΩ |
|||||||
Accuracy | Voltage ≤0.25kV:1MΩ~999MΩ ±5%,1.00GΩ~3000MΩ ±10% Voltage ≤0.50kV:1MΩ~999MΩ ±5%,1.00GΩ~10000MΩ ±10% Voltage ≤1.00kV:1MΩ~999MΩ ±5%,1.00GΩ~10000MΩ ±7% |
|||||||
Timer | Range | 0~999.9s | ||||||
Resolution | 0.1s | |||||||
Accuracy | ±(1%+50ms) | |||||||
Memory group | 20 | |||||||
Test step | 8 |